[ Modélisation hydraulique du réseau d’adduction d’eau potable (AEP) de la ville de Korhogo ]
Volume 52, Issue 1, December 2020, Pages 161–177
Franck Maxime Gnamba1, Oulaï Jean Gauthier Kpan2, Wilfried N’Zue3, and Yeï Marie Solange4
1 Département des Géosciences, Université Paleforo Gon Coulibaly (UPGC) de Korhogo, BP 1328 Korhogo, Côte d'Ivoire
2 Département de Géosciences, UFR des Sciences Biologiques, Université Peleforo Gon Coulibaly, BP 1328 Korhogo, Côte d’Ivoire
3 Département de Géosciences, UFR des Sciences Biologiques, Université Peleforo Gon Coulibaly, BP 1328 Korhogo, Côte d’Ivoire
4 Laboratoire des Sciences et Techniques de l’Eau et de l’Environnement (LSTEE), UFR des Sciences de la Terre et des Ressources Minières (STRM), Université Félix Houphouët-Boigny, 22 BP 582 Abidjan 22, Côte d’Ivoire
Original language: French
Copyright © 2020 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
This work aims to design a hydraulic model to know the current operation of the drinking water supply network for Korhogo city and to carry out corrective simulations to improve it. To achieve this, we used the EPANET software, to design and simulate the hydraulic model operation using the equal staffing method at each Request Node (DEN). In addition, based on an annual growth rate of 2.08%, the population of the city of Korhogo as well as the total water needs were estimated for different horizons and staffing scenarios. The results indicate that the overall average needs of the city in drinking water for an endowment 45 l/j/ hab. are respectively 678 m3/h for 2020, 750 m3/h for 2025, 830 m3/h for 2030, 1020 m3/h for 2040 and 1252 m3/h for 2050. The simulation of the network with the current injected flow which is 100 l/s, highlight some pressure and speed anomalies. Indeed, the network presents several negative or no conform pressures and unsatisfactory speeds (lower than 0.5 m/s and higher than 2 m/s). The network is apparently undersized and cannot meet the current and future needs of the city. Corrective simulations for optimal network operation until 2030 suggest positive pressures and speeds throughout the city with an endowment of 45 l/j/hab.
Author Keywords: Hydraulic modeling, drinking water network, EPANET, Korhogo, Côte d’Ivoire.
Volume 52, Issue 1, December 2020, Pages 161–177
Franck Maxime Gnamba1, Oulaï Jean Gauthier Kpan2, Wilfried N’Zue3, and Yeï Marie Solange4
1 Département des Géosciences, Université Paleforo Gon Coulibaly (UPGC) de Korhogo, BP 1328 Korhogo, Côte d'Ivoire
2 Département de Géosciences, UFR des Sciences Biologiques, Université Peleforo Gon Coulibaly, BP 1328 Korhogo, Côte d’Ivoire
3 Département de Géosciences, UFR des Sciences Biologiques, Université Peleforo Gon Coulibaly, BP 1328 Korhogo, Côte d’Ivoire
4 Laboratoire des Sciences et Techniques de l’Eau et de l’Environnement (LSTEE), UFR des Sciences de la Terre et des Ressources Minières (STRM), Université Félix Houphouët-Boigny, 22 BP 582 Abidjan 22, Côte d’Ivoire
Original language: French
Copyright © 2020 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
This work aims to design a hydraulic model to know the current operation of the drinking water supply network for Korhogo city and to carry out corrective simulations to improve it. To achieve this, we used the EPANET software, to design and simulate the hydraulic model operation using the equal staffing method at each Request Node (DEN). In addition, based on an annual growth rate of 2.08%, the population of the city of Korhogo as well as the total water needs were estimated for different horizons and staffing scenarios. The results indicate that the overall average needs of the city in drinking water for an endowment 45 l/j/ hab. are respectively 678 m3/h for 2020, 750 m3/h for 2025, 830 m3/h for 2030, 1020 m3/h for 2040 and 1252 m3/h for 2050. The simulation of the network with the current injected flow which is 100 l/s, highlight some pressure and speed anomalies. Indeed, the network presents several negative or no conform pressures and unsatisfactory speeds (lower than 0.5 m/s and higher than 2 m/s). The network is apparently undersized and cannot meet the current and future needs of the city. Corrective simulations for optimal network operation until 2030 suggest positive pressures and speeds throughout the city with an endowment of 45 l/j/hab.
Author Keywords: Hydraulic modeling, drinking water network, EPANET, Korhogo, Côte d’Ivoire.
Abstract: (french)
L’objectif de ce travail est de concevoir un modèle hydraulique permettant de connaître le fonctionnement actuel du réseau d’alimentation en eau potable (AEP) de la ville de Korhogo, et faire des simulations correctives pour l’améliorer. Pour y parvenir, nous avons utilisé le logiciel EPANET, pour concevoir et simuler le fonctionnement du modèle hydraulique en s’appuyant la méthode de dotation égale à chaque nœud de demande (DEN). En outre, en se basant sur un taux d’accroissement annuel de 2,08%, la population de la ville de Korhogo ainsi que les besoins totaux en eau ont été estimés pour différents horizons et scénarios de dotation. Les résultats indiquent que Les besoins moyens totaux de la ville en eau potable pour une dotation 45 l/j/hab. sont respectivement de 678 m3/h en 2020, 750 m3/h en 2025, 830 m3/h en 2030, 1020 m3/h en 2040 et 1252 m3/h en 2050. La simulation du réseau avec le débit actuel injecté qui est 100 l/s/ (soit une dotation d’environ 32 l/j/hab.) met en évidence de nombreuses anomalies de pressions et de vitesses. En effet, le réseau présente plusieurs conduites avec pressions faibles et des vitesses non satisfaisantes (inférieures à 0.5 m/s et supérieures à 2 m/s). Il est à priori, sous dimensionné et ne peut satisfaire les besoins actuels et futurs de la ville. Les simulations pour un fonctionnement optimal du réseau jusqu’en 2030 laissent entrevoir avec une dotation de 45 l/j/hab. des pressions et des vitesses positives dans la totalité de la ville.
Author Keywords: Modélisation hydraulique, réseau d’alimentation en eau potable, EPANET, Korhogo, Côte d’Ivoire.
How to Cite this Article