[ Contamination bactérienne des surfaces et équipements aux services de réanimation et unités de soins intensifs: Quel rôle pour l’équipe en prévention and contrôle des infections (PCI) ? ]
Volume 60, Issue 1, April 2022, Pages 30–45
Mounir Arai1, M. El Feniche2, M. Ouhadous3, H. Laajane4, L. Barrou5, and K. Zerouali6
1 Faculté de médecine et de pharmacie, Université Hassan II - Casablanca, Morocco
2 Faculté de médecine et de pharmacie de Rabat, Université Mohammed V de Rabat, Morocco
3 Service d’Hygiène Hospitalière-CLIN, CHU IBN Rochd, Casablanca, Morocco
4 Hassan II Université of Casablanca, Morocco
5 Réanimation chirurgicale, CHU IBN Rochd, Casablanca, Morocco
6 Laboratoire de microbiologie, Faculté de médecine et de pharmacie, Université Hassan II - Casablanca, Morocco
Original language: French
Copyright © 2022 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Introduction: Microbiological control of the environment in intensive care units is an integral part of the prevention of nosocomial infections and the control of outbreaks involving multidrug-resistant bacteria (MDR). The infection prevention and control team is at the heart of this approach. Particular concerns are the maintenance of a safe and hygienic care environment, and the minimization of microbial contamination of surfaces and equipment. The objective of our work was to determine the team's approach to the management of environment-related infections in intensive care units, to determine the bacterial ecology of these units, to specify the most contaminated sites and to present preventive and corrective actions. Method: A quantitative and qualitative study of the microbiological control of the environment was carried out between January 2018 and December 2020 at the level of intensive care units (ICU), and described the pre, per and post-microbiological processes applied to the hospital environment. Results: Of 350 samples collected, 33% were positive. The overall distribution of multidrug-resistant bacteria (MDR) isolated showed a predominance of gram-negative bacilli (GNB). The hygienists were responsible for the development and implementation of an environmental risk prevention plan including surveillance, prevention, training and evaluation. Conclusion: Our results showed that equipment and surfaces in intensive care units were heavily contaminated with multi-resistant bacteria. The control of this risk must be implemented through a multimodal strategy, with the intervention of a team specialized in the field.
Author Keywords: Contamination, environment, intensive care unit, infection prevention, control team.
Volume 60, Issue 1, April 2022, Pages 30–45
Mounir Arai1, M. El Feniche2, M. Ouhadous3, H. Laajane4, L. Barrou5, and K. Zerouali6
1 Faculté de médecine et de pharmacie, Université Hassan II - Casablanca, Morocco
2 Faculté de médecine et de pharmacie de Rabat, Université Mohammed V de Rabat, Morocco
3 Service d’Hygiène Hospitalière-CLIN, CHU IBN Rochd, Casablanca, Morocco
4 Hassan II Université of Casablanca, Morocco
5 Réanimation chirurgicale, CHU IBN Rochd, Casablanca, Morocco
6 Laboratoire de microbiologie, Faculté de médecine et de pharmacie, Université Hassan II - Casablanca, Morocco
Original language: French
Copyright © 2022 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract
Introduction: Microbiological control of the environment in intensive care units is an integral part of the prevention of nosocomial infections and the control of outbreaks involving multidrug-resistant bacteria (MDR). The infection prevention and control team is at the heart of this approach. Particular concerns are the maintenance of a safe and hygienic care environment, and the minimization of microbial contamination of surfaces and equipment. The objective of our work was to determine the team's approach to the management of environment-related infections in intensive care units, to determine the bacterial ecology of these units, to specify the most contaminated sites and to present preventive and corrective actions. Method: A quantitative and qualitative study of the microbiological control of the environment was carried out between January 2018 and December 2020 at the level of intensive care units (ICU), and described the pre, per and post-microbiological processes applied to the hospital environment. Results: Of 350 samples collected, 33% were positive. The overall distribution of multidrug-resistant bacteria (MDR) isolated showed a predominance of gram-negative bacilli (GNB). The hygienists were responsible for the development and implementation of an environmental risk prevention plan including surveillance, prevention, training and evaluation. Conclusion: Our results showed that equipment and surfaces in intensive care units were heavily contaminated with multi-resistant bacteria. The control of this risk must be implemented through a multimodal strategy, with the intervention of a team specialized in the field.
Author Keywords: Contamination, environment, intensive care unit, infection prevention, control team.
Abstract: (french)
Introduction: Le contrôle microbiologique de l'environnement dans les services de réanimation fait partie intégrante de la prévention des infections nosocomiales et du contrôle des épidémies impliquant des bactéries multirésistantes (BMR). L’équipe en prévention et control des infections est au cœur de cette démarche. Les préoccupations particulières sont le maintien d'un environnement de soins sûr et hygiénique, et la minimisation de la contamination microbienne des surfaces et des équipements. Objectif de notre travail était de déterminer la démarche de l’équipe dans la gestion des infections liées à l’environnement dans les services de réanimation, déterminer l’écologie bactérienne de ces services, préciser les sites les plus contaminés et présenter les actions préventives et correctives. Méthode: C’est une étude quantitative et qualitative du contrôle microbiologique de l'environnement a été réalisée entre janvier 2018 et décembre 2020 au niveau des unités de réanimation et de soins intensifs (USI), et a décrit les processus pré, per et post-microbiologiques appliqués à l'environnement hospitalier. Résultats: Sur les 350 échantillons prélevés, 33% étaient positifs. La distribution globale des bactéries multirésistantes (BMR) isolées a montré une prédominance des bacilles à Gram négatif (GNB). Les hygiénistes étaient responsables de l'élaboration et de la mise en œuvre de plan de prévention des risques environnementaux comprenant la surveillance, la prévention, la formation et l'évaluation. Conclusion: Nos résultats ont montré que le matériel et les surfaces des unités de soins intensifs étaient fortement contaminés par les bactéries multi résistantes.la maitrise de ce risque, doit être mise en œuvre grâce à une stratégie multimodale, avec intervention d’une équipe spécialisée dans le domaine.
Author Keywords: Contamination, Environnement, Unité de soins intensifs, Equipe en prévention, controle des infections.
How to Cite this Article
Mounir Arai, M. El Feniche, M. Ouhadous, H. Laajane, L. Barrou, and K. Zerouali, “Bacterial contamination of surfaces and equipment in intensive care units: What is the role of the infection prevention and control (IPC) team?,” International Journal of Innovation and Scientific Research, vol. 60, no. 1, pp. 30–45, April 2022.